Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-TT RFL Electronics Inc.
January 31, 2008 28 (973) 334-3100
“S” CODES
“S” codes appear in response to a “STATUS?” query. There are four “S” codes for the RFL DS-
TT. Like the “P” codes, each “S” code is a number displayed in both decimal and binary form.
A typical response to a “STATUS?” query looks like this:
*OK
CHANNEL CARD 3, TYPE 118
>>>(alert or alarm message here, if there is one)<<<
S01 = 3 (B00000011)
S01 = 5 (B00000101)
S01 = 4 (B00000100)
S01 = 196 (B01100100);
These codes provide information on the status of several conditions on the RFL DS-TT module.
Table 8 lists the meaning of all “S” codes for the RFL DS-TT module.
Table 8. Remote status messages (“S” codes)
Code Bits used Value Description
S01
B 0 0 0 0 0 0 0 0
...
0
Function 1 input
inactive
1 active
B 0 0 0 0 0 0 0 0
...
0
Function 2 input
inactive
1 active
B 0 0 0 0 0 0 0 0
...
0
Function 3 input
inactive
1 active
B 0 0 0 0 0 0 0 0
...
0
Function 4 input
inactive
1 active
B 0 0 0 0 0 0 0 0
...
0
Function 1 output
inactive
1 active
B 0 0 0 0 0 0 0 0
...
0
Function 2 output
inactive
1 active

Table of Contents