CARD CONFIGURATION
1. Module Enable (Service On)
The Module Enable box can be checked or unchecked.
For the NCM module to be In Service, check the Module Enable box.
For the NCM module to be Out Of Service, uncheck the Module Enable box.
2. Time Slot
The Time Slot can be set from 1-24 for T1 networks and from 1-31 for E1 networks. Click on the up or
down arrows to make the selection.
3. Data Bus A Direction & Data Bus B Direction
Bus A can be enabled or disabled, and Bus B can be enabled or disabled. Enabling or disabling Bus A
and Bus B is mode dependent in accordance with the table below.
Mode Bus A Bus B Application
Broadcast enabled disabled The NCM mode will be Terminal broadcast or DI-A broadcast
disabled enabled The NCM mode will be DI-B broadcast
enabled enabled The NCM mode will be D&I broadcast
disabled disabled (Not a valid setting. The NCM module is disabled)
NMS enabled disabled The NCM mode will be Terminal NMS or DI-A NMS
disabled enabled The NCM mode will be DI-B NMS
enabled enabled The NCM mode will be D&I NMS
disabled disabled (Not a valid setting. The NCM module is disabled)
Master enabled disabled The NCM mode will be Terminal Master or DI-A Master
disabled enabled The NCM mode will be DI-B Master
enabled enabled The NCM mode will be D&I Master
disabled disabled (Not a valid setting. The NCM module is disabled)
D&I Slave enabled disabled The NCM mode will be D&I Slave and the Master NCM node
is in the A direction.
disabled enabled The NCM mode will be D&I Slave and the Master NCM node
is in the B direction.
enabled enabled (Not a valid setting. The NCM module is disabled)
disabled disabled (Not a valid setting. The NCM module is disabled)
D&I End enabled disabled The NCM mode will be Terminal End Slave or DI-A End Slave
disabled enabled The NCM mode will be DI-B End Slave
enabled enabled (Not a valid setting. The NCM module is disabled)
disabled disabled (Not a valid setting. The NCM module is disabled)