FIRMWARE UPDATE PROCEDURE FOR MFP MACHINES
SM 5-93 B121 Series/B259 Series
Service
Tables
8. To Select a module: press
the OK key.
• The part numbers for the
version currently installed
(“ROM”) and the version on the
SD card that is to be installed
(“New”) can be displayed by
pressing the right scroll key
(arrow).
Example: ROM: B6585902B
New: B6585902C
• The firmware versions can be
displayed by pressing the right
scroll key again.
Example: ROM: 0.40.03
New: 0.40.04
• The display returns to the
firmware display name if the
right scroll key is pressed a
third time.
Example: System/Copy
9. Use the up and down scroll keys to scroll to the firmware you wish to install.
• If you wish to install the following firmware simultaneously, press the START
key. The scroll keys can be used to confirm that this firmware has been selected
(highlighted with a dark background).
Engine, FCU, Scanner, Printer, Printer Font, Security Module
• Please note that the following firmware cannot be updated simultaneously. The
update procedure must be repeated for each individually.
System/Copy, ServiceCardNetFile, ServiceCardNIB, ServiceCardFAX,
ServiceCardWebSystem.
B121S917.WMF
B121S917.WMF
B121S917.WMF
B121S917.WMF
Program UpDate Menu P.01
ROM: B6585902B
NEW: B6585902C
Exit
Program UpDate Menu P.02
ROM: 0.40.03
New: 0.40.04
Exit
Exit
Program UpDate Menu P.01
Printer
Exit
Rev. 09/2004
⇒
Firmware Display
System/Copy