Configuring the fieldbus
7.6 Communication via RS485
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
155
No.
Description
6A hex
Request not included / task is not supported
(the valid request identifications can be found
in table "Request identifications controller → inverter")
6B hex
No change access for a controller that is enabled
(operating status of the inverter prevents
a parameter change)
86 hex
Write access only for commissioning (p0010 = 15)
(operating status of the inverter
prevents a parameter change)
87 hex
Know-how protection active, access locked
C8 hex
Change request below the currently valid limit
(change request to a value that lies within
the "absolute" limits, but is however below the currently valid lower limit)
C9 hex
Change request above the currently valid limit
(example: a parameter value is too large for
the inverter power)
CC hex
Change request not permitted
(change is not permitted as the access code is not
available)
Parameter number
Parameter numbers < 2000
PNU = parameter number.
Write the parameter number into the PNU (PKE bit 10 ... 0).
Parameter numbers
≥ 2000
PNU = parameter number
- offset.
Write the parameter number minus the offset into the PNU
(PKE bit
100).
Write the offset in the page index (IND bit 158).
Table 7- 14 Offset and page index of the parameter numbers
Parameter number
Offset
Page index
Hex
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
0000 … 1999
0
0 hex
0
0
0
0
0
0
0
0
2000 … 3999
2000
80 hex
1
0
0
0
0
0
0
0
6000 … 7999
6000
90 hex
1
0
0
1
0
0
0
0
8000 … 9999
8000
20 hex
0
0
1
0
0
0
0
0
10000 … 11999
10000
A0 hex
1
0
1
0
0
0
0
0
20000 … 21999
20000
50 hex
0
1
0
1
0
0
0
0
30000 … 31999
30000
F0 hex
1
1
1
1
0
0
0
0
60000 … 61999
60000
74 hex
0
1
1
1
0
1
0
0
Indexed parameters
For indexed parameters, you must write the index as hex value into the subindex
(IND bit 7 … 0).