EasyManua.ls Logo

Siemens SINAMICS G120 - Two-Wire Control, Method 3

Siemens SINAMICS G120
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting functions
8.2 Inverter control
Inverter with CU230P-2 Control Units
232 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
8.2.4
Two-wire control, method 3
You switch the motor on and off using a control command (ON/OFF1) and at the same time
selecting clockwise motor rotation. You also use the other control command to switch the
motor on and off, but in this case you select counter-clockwise rotation for the motor.
Unlike method 2, the inverter will accept the control commands at any time, regardless of the
motor speed.
Figure 8-5 Two-wire control, method 3
Table 8- 4 Function table
ON/OFF1 clockwise
rotation
ON/OFF1 counter-
clockwise rotation
Function
0
0
OFF1: The motor stops.
1
0
ON: Clockwise motor rotation.
0
1
ON: Counter-clockwise motor rotation.
1
1
OFF1: The motor stops.
Parameter
Description
p0015 = 18
Macro drive unit
Controlling the motor using the
digital inputs of the inverter:
DI 0
DI 1
ON/OFF1
clockwise rotation
ON/OFF1 counter-
clockwise rotation
Advanced setting
Interconnecting control commands with digital inputs of your choice (DI x).
p3330[0n] = 722.x
BI: 2-3-WIRE control command 1 (ON/OFF1 clockwise rotation)
p3331[0n] = 722.x
BI: 2-3-WIRE control command 2 (ON/OFF1 counter-clockwise rotation)
Example
p3331[0n] = 722.2 DI 2: ON/OFF1 counter-clockwise rotation
Also see section Digital inputs (Page 94).

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals