Setting functions
8.2 Inverter control
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
231
8.2.3
Two-wire control, method 2
You switch the motor on and off using a control command (ON/OFF1) and at the same time
select clockwise motor rotation. You also use the other control command to switch the motor
on and off, but in this case you select counter-clockwise rotation for the motor.
The inverter only accepts a new control command when the motor is at a standstill.
Figure 8-4 Two-wire control, method 2
Table 8- 3 Function table
ON/OFF1
clockwise rotation
ON/OFF1 counter-
clockwise rotation
Function
0
0
OFF1: The motor stops.
1
0
ON: Clockwise motor rotation.
0
1
ON: Counter-clockwise motor rotation.
1 1 ON: The motor direction of rotation is based on the signal
that assumes status "1" first.
Parameter
Description
p0015 = 17
Macro drive unit
Controlling the motor using the
digital inputs of the inverter:
DI 0
DI 1
ON/OFF1
clockwise rotation
ON/OFF1
counter-clockwise
rotation
Advanced setting
Interconnecting control commands with digital inputs of your choice (DI x).
p3330[0n] = 722.x
BI: 2-3-WIRE control command 1 (ON/OFF1 clockwise rotation)
p3331[0n] = 722.x
BI: 2-3-WIRE control command 2 (ON/OFF1 counter-clockwise rotation)
Example
p3331 = 722.0 DI 0: ON/OFF1 counter-clockwise rotation
Also see section Digital inputs (Page 94).