EasyManua.ls Logo

Siemens SINAMICS G120 - Compound Braking

Siemens SINAMICS G120
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting functions
8.7 Application-specific functions
Inverter with CU230P-2 Control Units
278 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
8.7.3.3
Compound braking
Typical applications for compound braking include:
Centrifuges
Saws
Grinding machines
Horizontal conveyors
For these applications, the motor is normally operated with a constant speed, and is only
braked down to standstill after longer periods of time.
Principle of operation
Figure 8-21 Motor brakes with and without active compound braking
Compound braking prevents the DC-link voltage increasing above a critical value. The
inverter activates compound braking depending on the DC-link voltage. Above a DC-link
voltage threshold (r1282), the inverter adds a DC current to the motor current. The DC
current brakes the motor and prevents an excessive increase in the DC-link voltage.
Note
Compound braking is possible only with the U/f control.
Compound braking does not operate in the following cases:
The "flying restart" function is active
DC braking is active
Vector control is selected

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals