Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
406 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Power-dependent data, PM260
Table 12- 40 PM260, IP20, Frame Sizes D - 3 AC 660 V … 690 V
Order No. - Unfiltered
Order No. - Filtered
Rated / LO power
Rated / LO input current
Rated / LO Output current
11 kW
13 A
15 kW
18 A
18.5 kW
22 A
HO power
HO input current
7.5 kW
10 A
11 kW
13 A
15 kW
18 A
Power losses, unfiltered
Required cooling air flow
Cross section of line and motor cable 2,5 … 16 mm
2
4 … 16 mm
2
6 … 16 mm
2
Tightening torque for line and motor cable
Weight, unfiltered
22 kg
22 kg
22 kg
Table 12- 41 PM260, IP20, Frame Sizes F - 3 AC 660 V … 690 V
Order No. - Unfiltered
Order No. - Filtered
0BH32-2UA1
0BH33-0UA1
0BH33-7UA1
Rated / LO power
Rated / LO input current
Rated / LO Output current
30 kW
34 A
37 kW
41 A
55 kW
60 A
HO power
HO input current
22 kW
26 A
30 kW
34 A
37 kW
41 A
Power losses, unfiltered
Required cooling air flow
Cross section of line and motor cable 10 … 35 mm
2
16 … 35 mm
2
25 … 35 mm
2
Tightening torque for line and motor cable
Weight, unfiltered
56 kg
56 kg
56 kg