Configuring the fieldbus
7.4 PROFIenergy profile for PROFINET
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
135
7.4
PROFIenergy profile for PROFINET
PROFIenergy is an energy management system for production plants, based on the
PROFINET communication protocol. The functionality is certified and described in the
PROFIenergy profile of the PNO.
The inverter supports the PROFIenergy profile V1.1 with the following functions:
PROFIenergy functions of the inverter
The control transfers the PROFIenergy commands in acyclic operation to the inverter in data
set 80A0 hex.
Parameters r5600 to p5614 are reserved for PROFIenergy functions in the inverter.
The PROFIenergy status is output in r5600.
The following commands and queries are available for the control:
PROFIenergy control commands
Start_Pause
Switches from operating state S1 or S2 (start inhibit or start readiness) to energy-saving
mode.
Switches from energy-saving mode to the operating state.
START_Pause_with_time_response
Switches from operating state S1 or S2 (start inhibit or start readiness) to energy-saving
mode and also specifies the transition times in the command response.
End_Pause
Switches from energy-saving mode to the operating state.
Cancels the switching from the operating state to the energy-saving mode.
PROFIenergy status requests
List_Energy_Saving_Modes
Determines all supported energy-saving modes.
GeLMode
Determines information about the selected energy-saving mode.
PEM_Status
Determines the current PROFienergy status.
PEM_Status_with_CTTO
Determines the current PROFienergy status, such as the PEMStatus, together with the
regular transition time to the operating state.
PEldentify
Determines the supported PROFienergy commands.
Query Version
Shows the implemented PROFienergy profile.
Get_Measurement_List
This command returns the measured value IDs that can be accessed using the
"Get_Measurement_Values" command.

Table of Contents