Description
3.4 System components for the Power Modules
Inverter with CU230P-2 Control Units
36 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
-wave filter at the inverter outputs almost sinusoidal voltages to
the motor, so that you can use standard motors without special cables.
The maximum permissible length of motor feede
r cables is increased to
m.
en using a sine-wave filter:
Operation is only permissible with pulse frequencies from 4 kHz to
8 kHz.
From 110 kW power rating of the Power Modules (according to the
rating plate) only 4 kHz is permissible.
The inverter power is reduced by 5%.
The maximum output frequency of the inverter is 150 Hz at 380 V to
480 V.
Operation and commissioning may only be performed with the motor
connected, as the sine-wave filter is not no-load proof.
An output reactor is superfluous.
for FSF
Sine-wave filter for PM240 Power Module
FSA …0BE13-7UA0, …0BE15-5UA0,
0.37 kW … 0.75 kW 6SL3202-0AE20-3SA0
FSB
FSC
FSD
FSF
FSGX
…0XE42-0UA0 250 kW 6SL3000-2CE34-1AA0