Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
401
12.2.4.2
General data, PM250
Feature
Version
Line voltage
380 V ... 480 V 3-ph. AC ±10%
Output voltage
0 V 3-ph. AC … input voltage x 0.87 (max.)
Input frequency
47 Hz63 Hz
Power factor λ
0.9
Starting current
Less than the input current
Pulse frequency (factory
setting)
4 kHz
The pulse frequency can be increased up to 16 kHz in 2 kHz steps. An increase in the pulse
frequency results in a lower output current.
Electromagnetic
compatibility
The devices in compliance with EN 61800-3: 2004 are suitable for Category C1 and C2
environments. For details, see the Hardware Installation Manual, Appendix A2
Braking methods
DC braking, energy recovery (up to 100% of the output power)
Degree of protection
IP20 chassis units
Operating temperature LO without derating:
HO without derating:
LO/HO with derating:
0 °C … +40 °C
0 °C … +50 °C
to 60 °C
For details, see the Hardware
Installation Manual.
Storage temperature
-40 °C … +70 °C
Relative humidity
< 95% - condensation not permissible
Dirt and contamination
Protected according to pollution degree 2 to EN 61800-5-1: 2007
Environmental requirements Protected against damaging chemical substances according to environmental class 3C2 to
EN 60721-3-3; 1995
Shock and vibration
Long-term storage in the transport packaging according to Class 1M2 to EN 60721-3-1:
1997
Transport in the transport packaging according to Class 2M3 to EN 60721-3-2: 1997
Vibration during operation according to Class 3M2 to EN 60721-3-3: 1995
Installation altitude without derating:
with derating:
up to 1000 m above sea level
up to 4000 m above sea level
For details, see the Hardware
Installation Manual
Standards UL, CE, CE, SEMI F47
The drive only satisfies the UL requirements when UL-certified fuses are used.