EasyManua.ls Logo

Siemens SINAMICS G120 - Installing Control Unit

Siemens SINAMICS G120
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing
4.4 Installing Control Unit
Inverter with CU230P-2 Control Units
58 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
4.4
Installing Control Unit
Installing the Control Unit on an IP20 Power Module
Procedure
Proceed as follows to connect Power
Modules and Control Units:
1.
Locate the lugs at the rear of the Control
Unit in the matching recesses of the
Power Module.
2.
Mount the Control Unit onto the Power
Module so that it audibly snaps into place.
The Power Module and the Control Unit are now connected with one another.
To remove the Control Unit, press on the release button on the Power Module and withdraw
the Control Unit.
Installing the Control Unit on an IP55 Power Module
Procedure for installing a Control Unit
Please proceed as follows:
1.
Ensure that the device is
disconnected from the power
supply.
2.
Unscrew the cover of the power
section.
3.
Locate the lugs at the rear of the
Control Unit in the matching
recesses of the Power Module.
4.
Mount the Control Unit onto the
Power Module so that it audibly
snaps into place.
5.
Refasten the cover of the power
section.
You have now placed the Control Unit on the Power Module.