Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
408 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Compliance with standards
Standards EN 60146-1-1, EN 61800-2, EN 61800-3, EN 61800-5-1, EN 60204-1, EN 60529, UL508C,
CE marking According to EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC
and Machinery Directive No. 2006/42/EC
Radio interference
suppression
In accordance with the EMC product standard for variable-speed drives EN 61800-3,
"second environment"
1)
.
Application in "first environment" possible with line filters.
cULus (File No.: E192450), CE, c-Tick, GOST-R, KC
2)
2)
Ambient temperature -25 ... +55 °C -25 ... +70 °C
above –40 °
C
for 24 hours
0
... +40 °C
up to +50 °C with derating
Relative humidity
(no condensation)
Corresponds to class
5 to 95%
1K4 according to
5 ... 95% at 40 °C
2K3 according to
5 ... 95%
3K3 according to
Environmental class /
harmful chemical substances
1C2 according to
2C2 according to
3C2 according to
Organic/biological influences 1B1 according to
2B1 according to
3B1 according to
2 according to EN 61800-5-1
Installation altitude Up to 1000 m above sea level without derating,
> 1000 m above sea level with derating (see "Derating data")
2)
2)
Vibrational load
- Displacement
- Acceleration
Fc test according to
EN 60068-2-6
±1.5 mm for 5 ... 9 Hz
0.5 g for 9 ... 200 Hz
Fc test according to
EN 60068-2-6
±1.5 mm for 5 ... 9 Hz
0.5 g for 9 ... 200 Hz
Fc test according to
EN 60068-2-6
0.075 mm for 10 ... 58 Hz
9.81 ma/s² (1 x g) for
Shock load
- Displacement
Fc test according to
EN 60068-2-6
±1.5 mm for 5 ... 9 Hz
Test according to EN 60068-
2-27 (EA shock type)
49 ma/s² (5 x g)/30 ms
Deviations from the defined classes are shown in
italics
.
Standard construction: Devices installed in the switch cabinet with EMC-conform construction, line reactor uk = 2%,
shielded motor cable (e.g. Protoflex EMC) with max. 100 m cable length,
line perturbations according to EN 61000-2-4: Class 2, THD(U) total = 8% for typical line conditions (RSC > 30 ... 50);
THD(I) total: typical 30 … 45% (15 < RSC < 50);
2)
In transport packaging