IM2/4-76 SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
9006 DISPLAY_BLACK_TIME
H05
CR: A2
- Time for screen darkening BYTE 3/4
OP30, Emb OP30: 15, Emb:
15
0 60
Power On SW 2
9007 TABULATOR_SIZE
H05
CR: A2
- Tabulator length BYTE 3/4
OP30, Emb OP30: 4, Emb: 4
0 30
IMMEDIATE
LY
SW 2
9008 KEYBOARD_TYPE
H05
CR: A2
- Keyboard type
(0: OP, 1: MFII/QWERTY)
BYTE 3/4
Adv, Emb Adv: 0, Emb: 0
0 1
Power On SW3.6
9009 KEYBOARD_STATE
H05
CR: A2
- Keyboard shift response during ramp-up
(0: single, 2: CAPSLOCK)
BYTE 3/4
Adv, Emb Adv: 0, Emb: 2
0 2
Power On SW3.6
9011 DISPLAY_RESOLUTION_INCH
H05
CR: A2
- Display resolution for INCH system of measurement BYTE 3/4
Adv, Emb Adv: 4, Emb: 4
0 6
Power On SW5.1
9012 ACTION_LOG_MODE
H05
CR: IM2, IM4
- Set action mode for action log INTEGER 1/1
Adv, Emb Adv: 0xFE, Emb:
254
0 0xFFFF
Power On SW5.2
9013 SYS_CLOCK_SYNC_TIME
H05
CR: IM1
- Synchronization time for MMC/HMI time with PLC
Synchr. time for HMI/PLC time
REAL 0/0
Emb Emb: 0
0 199
Power On SW5.3
9014 USE_CHANNEL_DISPLAY_DATA
H05
CR: FBT,
FBSP, EMB,
ADV
- Use channel-specific display MDs INTEGER 3/4
Adv, Emb Adv: 0, Emb: 0
0 1
IMMEDIATE
LY
SW6.3
9015 DARKTIME_TO_PLC
CR: -
- BOOL 3/4
OP30, OP30: 0,
*** ***
Power On SW5
9016 SWITCH_TO_AREA
H05
CR: IAM, BE1
- Default boot menu can be selected INTEGER 3/4
OP30, Emb OP30: 20, Emb:
-1
-1 10000
Power On SW6.3
9017 PLC_HOTKEY
CR:
- STRING 3/4
OP30, OP30:
DB0.DBB0.0,
*** ***
Power On