Commissioning HMI Advanced (IM4) 08/2005
2 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
IM4/2-102 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; DirectoryPath specifies the directory of the log files
DirectoryPath = D:\AC_LOG
; FileSize gives the upper size limit of the log file, in bytes
FileSize = 40000
; VariableN allows a maximum of 10 NC/PLC variables to be monitored.
; The first parameter is numeric and provides the monitoring mode:
; if Bit0 is set and the value of the variable changes, the value changes
; are logged in the ActionLog files
; if Bit1 is set and the value of the variable changes, the ActionLog files
; are commited to disk
; Default : Variable0 = 1, /Channel/ProgramInfo/msg
; monitor part program messages
Variable0 = 1, /Channel/ProgramInfo/msg
; CommittedAlarms holds up to 10 alarm numbers separated by commas.
; Changes in these alarms commit
; ActionLog data to disk
; Default: CommittedAlarms = 3000
; commit on emergency stop
CommittedAlarms = 3000
; for working with SIMNC, uncomment the following section descriptor
; this causes a sim-process to be started that will be used as a machine
;[NCDDE_STARTCMD]
CMD=dpncsim.exe /T:1 /P:0
WND_CLASS=SIM_LOCAL_NCK
WND_NAME=SIM_LOCAL_NCK
STARTUP_TIMEOUT=50
;WAIT_SYNC_MESSAGE=
CLOSE_TIMEOUT=30
[WP_SELECT]
; for displaying a message that TOA/TMA-data on NCK will be overwritten
;TOA_WARNING_MESSAGE = yes/no
TOA_WARNING_MESSAGE=yes
[PCU]
; device name of PCU for USB local
UsbFront=G: ' access rights of the PCU USB device (0-7) for the application
machine, program and services
AccessMachine=7
AccessProgram=7
AccessServices=7
[PROGRAM]
;0=message to user if a program of the DAT-file for MCSE was not
; found or a channel doesn't exist (default)
;1=skip all entries of DAT-file if the program or a channel was not found
IgnoreMissingProgramAndChan=0

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals