4-40
PDW-700/V1 (E)
LEVEL ADJUST Display (Adjusting output signal level)
Item Setting Function
VBS VIDEO LEVEL (_99 to 99) Adjusts the composite signal video level
HD-Y LEVEL (_99 to 99) Adjusts the Y level of the HD component signal
TEST OUT SELECT VBS/Y/R/G/B/LCD Selects the video signal that is output from the TEST OUT connector
BATTERY 1 Display (Setting-1 the battery-related items)
Item Setting Function
Info BEFORE END 5% to 100% (5% steps)
Used when a BP-GL65/GL95 Battery Pack is used. Sets the remaining power
(% value) of the battery at which the BEFORE END warning should be issued
*1
Info END 0%/1%/2%/3%/4%/5%
Used when a BP-GL65/GL95 Battery Pack is used. Sets the remaining power
(% value) of the battery at which the END warning should be issued
*2
Sony BEFORE END 11.5 to 17.0 V (0.1V steps)
Used when a BP-L60S/L80S Battery Pack is used. Sets the voltage level of the
battery at which the BEFORE END warning should be issued
*1
Sony END 11.0 to 11.5 V (0.1V steps)
Used when a BP-L60S/L80S Battery Pack is used. Sets the voltage level of the
battery at which the END warning should be issued
*2
Other BEFORE END 11.5 to 17.0 V (0.1V steps)
Used when a battery pack other than a Sony battery pack is used. Sets the
voltage level of the battery at which the BEFORE END warning should be
issued
Other END 11.0 to 14.0 V (0.1V steps)
Used when a battery pack other than a Sony battery pack is used. Sets the
voltage level of the battery at which the END warning should be issued
DC IN BEFORE END 11.5 to 17.0 V (0.1V steps)
Used when an external power source is connected to the DC IN connector
Sets the voltage level of the connected external power source at which the
BEFORE END warning should be issued
DC IN END 11.0 to 14.0 V (0.1V steps)
Used when an external power source is connected to the DC IN connector
Sets the voltage level of the connected external power source at which the END
warning should be issued
DETECTED BATTERY Info/Sony/Other/DC IN Displays the type of automatically detected battery
*1 : The setting of this item is overridden by the setting of Other BEFORE END when TYPE DETECTION in the BATTERY 2 page is set to “ OTHER” .
*2 : The setting of this item is overridden by the setting of Other END when TYPE DETECTION in the BATTERY 2 page is set to “ OTHER” .
M03 LEVEL ADJUST TOP
VBS VIDEO LEVEL : 0
HD-Y LEVEL : 0
TEST OUT SELECT : VBS
M04 BATTERY 1 TOP
Info BEFORE END : 5%
Info END : 0%
Sony BEFORE END :11.5V
Sony END :11.0V
Other BEFORE END :11.8V
Other END :11.0V
DC IN BEFORE END :11.8V
DC IN END :11.0V
DETECTED BATTERY : Info