166 Description Of Specific Functions
V560 Series High Performance Closed-Loop Vector Inverter User Manual
Triangular wave decreasing time is referred to the time spent from the upper boundary frequency to the lower
boundary frequency in swing frequency operation, that is, the deceleration time in the cycle of swing
frequency operation.
The sum of triangular wave rising time and decreasing time is the swing frequency operation cycle.
F6.2.53 Center frequency
setting of traverse
Setting range: 0.00~[F0.1.21] Factory default: 10.00
Frequency setting in the center of the swing frequency is referred to the center value of frequency converter
output frequency in the process of swing frequency operation.
Center frequency of practical output = [F6.2.53] + F0.1.16 certain set frequency