Description Of Specific Functions
V560 Series High Performance Closed-Loop Vector Inverter User Manual
173
7.30 PROCESS PID MULTI-STAGE SETTING (GROUP F7.1)
F7.1.27~F7.1.33 Process PID
multi-stage preset
Setting range: -100.0~100.0% Factory default: 0.0
This group of parameter defines the set value of process PID multi-stage operation. Set value is the relevant
percentage of process PID set value determined in F7.0.01.
Multi-stage operation of process PID can be flexibly realized with multifunction input terminal, please refer to
function instruction of given terminal 1, 2, 3(28~30) of multi-stage process PID of terminal function F3.0.00 ~
F3.0.08.
7.31 PROCESS PID SLEEPING FUNCTION (GROUP F7.2)
This function is valid when PID output conducts frequency order; Sketch is shown as below:
7.32 REVOLUTION SETTING AND FEEDBACK (GROUP F8.0)
Given
revolution
Torque limit
Given torque
Speed error
Feedback
revolution
K
D
K
d
S
Ts
1
1+T
d
S
1
+
-
+
+
+
[F8.1.30]
[F8.1.21]~[F8.1.28]
[F8.1.29]
Figure 7-60 Closed-loop block diagram of revolution
This group of parameter is valid with VC and SVC modes.
¾ Set value of awakens deviation is the relevant percentage of PID given value.
Figure 7-59 Sketch of PID sleeping function
[F7.2.38]
Output
frequency
Start
[F7.2.35]
Awaken
deviation[F7.2.37]
PID feedback
Time(T)
Time(T)
Stop
PID given
value
T<[F7.2.36] [F7.2.36]