Functional Parameter Table
V560 Series High Performance Closed-Loop Vector Inverter User Manual
87
6.2.50 OTHER CONFIGURATION PARAMETERS
Function
Code
Name Setting Range and Description
Minimum
Unit
Factory
Default
Change
Limit
FF.4.41
Cooling fan
control
_ _ _ X: Soft start function (effective for model
4T0370 and below)
0: No action 1: Act
_ _ X _: Air volume auto adjustment (effective
for model 4T0370 and below)
0: No action 1: Act
_ X _ _: Start time
0: Start immediately after power- on
1: Start after running
X _ _ _: Reserved
1 0101
FF.4.42
Operating panel
control options
_ _ _ X: Panel REV/JOG key function selection
0: REV (REV running key)
1: JOG (FWD jog key)
_ _ X _: Reserved
_ X _ _: Reserved
X _ _ _: Panel control selection (except STOP
key)
0: Standard panel interface control (can be
connected to monitoring panel via RS485)
1: RS485 port external panel control (standard
panel, only for monitoring)
2: Multifunctional terminal switching (Function
No. 40)
1 0000 ×
FF.4.43
Special function
configuration
_ _ _ X: Motor parameter identification
auto-start
0: Forbidden 1: Permitted
_ _ X _: Voltage vector composition mode
0: Three-phase composition
1: Two-phase composition
_ X _ _: Voltage small pulse shielding
0: Void 1: Effective
X _ _ _: SVC Revolution identification mode
0: Current open-loop mode
1: Current closed-loop mode (Reserved)
1 0001
FF.4.44
Asynchronous
motor
parameter
adaptive
correction
LED _ _ _ X: Stator resistance
0: Forbidden 1: Permitted
LED _ _ X _: Total leakage inductance
0: Forbidden 1: Permitted
LED _ X _ _: Rotor time constant
0: Forbidden 1: Permitted
LED X _ _ _: Torque increasing function
0: Void 1~5: Effective
1 0011
FF.4.45
Random
reference value
0~65535 1 R