Description Of Communication Protocol 225
V560 Series High Performance Closed-Loop Vector Inverter User manual
Slave Unit Response:
Slave Unit
Address
Function
Code
Sub-function
Code
High Digit
Sub-function
Code
Low Digit
Response
Data
High Digit
Response
Data
Low Digit
CRC Check
Low Digit
CRC Check
High Digit
01 08 00 0C 00 23 61 D1
5) Query the model description for frequency inverter
Host request:
Slave Unit Address Function Code CRC Check Low Digit CRC Check High Digit
01 11 C0 2C
Slave Unit Response:
Slave Unit
Address
Function
Code
Number
of Bytes
Model Data
Operation
Status
Extra Data
CRC Check
Low Digit
CRC Check
High Digit
01 11 10 00 00 01 05 60 FF
04 03 11 00 20
11 01 02 61 02
A5 5C
Model of frequency inverter: V560-4T1100G/4T1320P, frequency inverter in operation, production batch of
2011-2-3, version number: 6201.