EasyManua.ls Logo

Svantek SVAN 958A - Page 110

Svantek SVAN 958A
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
110
SVAN 958A User Manual
B(k) the Lden result (ccc the value in dB);
Y the Ltm3 result (ccc the value in dB);
Z the Ltm5 result (ccc the value in dB);
L(nn) the value L of the nn statistics (ccc the value in dB);
r the underrange flag (ccc equals to 0 or 1);
In case of results timestep other than measurement time, only VPMNR subset of results is available
Note: The value displayed on the screen during the result’s presentation will be sent out from the
instrument in the case when after the X code the nn is not given.
Note: For profiles 2 and 3 the L(nn) result is not calculated.
Note: The presented above order of the measurement results sent out by the instrument does
not depend on the order of the characters sent to the unit.
Note: In the case of Lden, the value k placed in the parenthesis after the code B, denotes the
kind of the currently measured result. The kind of the Lden result depends on the time during which the
measurements were performed (d denotes day, e denotes evening and n denotes night).
The corresponding values of k parameter and the kind of the measured Lden result are presented below:
k = 1 Ld result,
k = 2 Le result,
k = 3 Lde result,
k = 4 Ln result,
k = 5 Lnd result,
k = 6 Len result,
k = 7 Lden result.
Example: After sending to the instrument the following string:
#2,1,T?,V?,B?,P?,M?,R?,L50?;
one should receive the answer given below:
#2,1,T3,V0,P66.91,M64.55,R61.70,B(2)66.70,L(50)54.95;
The codes of the results in the case of SOUND DOSIMETER mode are defined as follows:
T time of the measurement (ccc value in seconds);
V the overload flag (ccc equals to 0 or 1);
P the PEAK value (ccc the value in dB);
M the MAX value (ccc the value in dB);
N the MIN value (ccc the value in dB);

Table of Contents