S the SPL value (ccc – the value in dB);
D the DOSE value (ccc – the value in %);
d the DOSE8h value (ccc – the value in %);
A the LAV value (ccc – the value in dB);
R the LEQ value (ccc – the value in dB);
U the SEL result (ccc – the value in dB);
u the SEL8 value (ccc – the value in dB);
E the E value (ccc – the value in Pa
2
h);
e the E8h value (ccc – the value in Pa
2
h);
I the LEPd value (ccc – the value in dB);
J the PSEL value (ccc – the value in dB);
Y the Ltm3 result (ccc – the value in dB);
Z the Ltm5 result (ccc – the value in dB);
L(nn) the value L of the nn statistics (ccc – the value in dB).
r the underrange flag (ccc equals to 0 or 1);
The codes of the results in the case of VLM mode are defined as follows:
T time of the measurement (ccc – value in seconds);
V the overload flag (ccc equals to 0 or 1);
P the P–P value (ccc – the value in dB);
Q the PEAK value (ccc – the value in dB);
M the MTVV value (ccc – the value in dB);
R the RMS value (ccc – the value in dB);
H the VDV value (ccc – the value in dB);
v the VEC value (ccc – the value in dB).
r the underrange flag (ccc equals to 0 or 1);
Example: After sending to the instrument the string:
#2,1,T?,V?,P?,R?;
one should receive the following answer:
#2,1,T3,V0,P76.92,R64.50;
The codes of the results in the case of Vibration Dose mode are defined as follows:
a the Current Dose value (ccc – the value in dB);
b the Daily Dose value (ccc – the value in dB);
c the Current Exposure value (ccc – the value in dB);
f the Daily Exposure value (ccc – the value in dB);
g the EAV Time value (ccc – value in seconds);
h time left to reach EAV value (ccc – value in seconds);
i the ELV Time value (ccc – value in seconds);
j time left to reach ELV value (ccc – value in seconds).
Example: After sending to the instrument the string:
#2,0,c?,f?,g?,h?;