(18) Standard Curve Setting Function
Standard curve of seven parameters (14 parameters in CA-550 and CA-560) can be set at six points or
less within the measurable range. Setting Standard Curve is performed by the Auto dilution or Manual
Entry. (Manual dilution analysis is available only in CA-550 and CA-560.) Two kinds of standard curves
can be set to one parameter (only in CA-550 and CA-560). Settings should be given to each parameter
individually.
(19) Analytical Algorithm corresponding to V-Lin-Integral (CA-550 and CA-560 only)
As a new analysis method, analytical algorithm equivalent to V-Lin-Integral is provided.
(20) APTT Initial Reaction Check Algorithm (CA-550 and CA-560 only)
An algorithm to check APTT’s initial reactions is newly provided.
(21) Detector Block Self-Checking Function (CA-550 and CA-560 only)
Besides the already-provided functions to adjust the detector block, a function is newly provided that the
analyzer self-monitors the state of the detector block and carry out auto calibration.
(22) Error Alert Function
1) Unit Error monitoring function
(i) Temperature of heater section
(ii) Shortage of reagent
(iii) Presence or absence of sample rack
(iv) Shortage of rinse solution
(v) Overflow from the waste bottle
(vi) Operation of mechanical parts
(vii) Operation of printer
(viii) Shortage of printer paper
(ix) Serial output
(x) Other self-diagnosis by service mode
2) Sample Abnormality monitoring function
(i) Upper and lower limit judgment (PT, APTT, Fbg, TTO, NT, TT, AT-III)
Display when the measured data exceeds the preset range.
(23) External Input/Output Function
The I/O terminal in accordance with RS-232C is provided as bit serial voltage I/O.
(24) Protection Function
1) Over-heat protection thermal fuse (Pipette Unit and Detector Block)
2) Mechanical stop switch
3) Light Shield cover open/close switch
4) Sampler position sensor
(25) Display Languages
Capable of displaying six languages such as Japanese, English, French, Italian, German, and Spanish.
Screen displays and messages should be consistent with those of existing models.
1.5 ACOUSTIC NOISE LEVEL
Noise level should be within the following values. (The measuring position is 1 meter from the front of the
product.
(1) Stand-by status: 58 dB or less
(2) Measuring operation status: 60 dB or less
Temporary noises (less than 65 dB continued within 5 seconds) are produced on occasions, such as home
positioning of X-Y table or syringe drive mechanism are not included.
CA-500 Series S/M 1-13 Revised December 2001 8