8 MALFUNCTION
8.8 MHL380 D
8.8.7 Loading equipment is not working
All travel and work functions are disabled.
Enable travel and work functions
h 5.1.7 Disabling all travel and work functions
Check the armrest switch and repair or replace
if necessary.
Oil supply to hydraulic pump interrupted.
Hydraulic pump has failed.
Have the hydraulic pump checked by a special-
ist, replace complete pump if necessary.
5 Main pressure relief valve has failed or is set
incorrectly.
Have the main pressure relief valve checked by
a specialist, replace complete pump if neces-
sary.
Engine temperature above 110°C.
h 4.7 Monitoring the machine during operation
8.8.8 Machine has reduced power
Engine has insufficient power.
Hydraulic oil level is too low.
Top up hydraulic oil to mark on sight glass.
Retighten the hose connections. Replace the
O-ring or seals.
Working pressure too low.
Have the main pressure relief valve adjusted by
a specialist; replace pump if necessary.
Check the load limit sensing control. Check if
fine mode is set to 0; set to 0 if necessary.
8.8.9 Machine is working too slowly and hydraulic fluid is getting hot
Main pressure relief valve set too low or
faulty.
Have the main pressure relief valve adjusted by
a specialist; replace pump if necessary.
Hydraulic pump has impermissible degree of
wear.
Incorrect hydraulic fluid.
Hydraulic fluid must be of the recommended
quality.
Hydraulic oil level is too low.
Top up hydraulic oil to mark on sight glass.
Oil cooler dirty or faulty.
Clean oil cooler, check and replace if neces-
sary.
6 Air in hydraulic system. Vent the pilot control.
Tighten connections with engine off and system
relieved of pressure.