3 TECHNICAL DATA
3.6 MHL380 D
3.5 Hydraulic system
Main pump Adjustable double displacement pump + sepa-
rate turning circle pump in closed circuit
Pump capacity
:
max. 64
0 l/min at
20
0 rpm in turning
circle at 1800 rpm
Working pressure:
max. 360 bar
The pump is regulated by the amount of cur-
rent required and thus pumps only the amount
of oil actually required by the consumers.
Power transfer between the pump and the diesel engine is monitored by the load limit sensing
control. The diesel engine is thus protected,
even in the partial throttle range, against ex-
cessive reductions in speed and overloads. As
such, load limit sensing control optimizes the
use of the available engine rating.
Additional pumps Gear pumps in the open circuit for supplying
auxiliary loads such as "Movable cab" or the
functions "Grab rotation", "Brake", "Pilot con-
trol", "Fan motor for hydraulic oil cooler",
"Steering" and "Oscillating axle".
Control block Control block in sector design – single-circuit
system
Oil cooler The fan speed is controlled thermostatically.
This ensures that the hydraulic system will
reach its operating temperature quickly and
stay at that level constantly. The reduction in
noise level produced by thermostatic control
and the resulting speed adjustment is benefi-
cial for both the operator and the environment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terex Fuchs MHL380 D and is the answer not in the manual?

Terex Fuchs MHL380 D Specifications

General IconGeneral
BrandTerex
ModelFuchs MHL380 D
CategoryConstruction Equipment
LanguageEnglish

Related product manuals