Surveying with the HiPer+
1-866-4TOPCON www.topconpositioning.com
3-15
11. Select the Base tab and set the following parameters
(Figure 3-9):
GPS/GLO at one time – enable
Antenna position – enter Lat, Lon, and Alt values.
OR
Click Get from receiver.
OR
Enable Averaged and enter the Averaged Span in
seconds, then click Apply. Click Tools->Reset
receiver and wait until the specified interval (span)
completes. Examine the Base coordinates on the
Base tab, they should correspond to the coordinates
obtained from the average. Click Refresh if the
coordinates are zeros.
NOTICE
The reference geodetic coordinates specified
here relate to the antenna L1 phase center.
Figure 3-9. Base Tab Configuration