Troubleshooting
Topcon HiPer+ Operator’s Manual
5-2
Power Problems
All HiPer+ receivers are preset in the factory as “Auto Mode” for
both the power and charger. If you want to check these settings,
1. Connect your receiver and computer and run PC-CDU (see
“Connecting the HiPer+ and a Computer” on page 2-5).
2. Once connected, click Configuration->Receiver.
3. On the General tab, view the Power and Charger fields.
These fields should be set to Auto. If not, change them to
Auto and click Apply.
TIP
Clearing the NVRAM will also return the
receiver to Auto Mode (see “Clearing the
NVRAM” on page 4-18).
Problem
The receiver does not power up.
Causes Solutions
The receiver may be in
Zero Power Mode.
Press the Reset key.
If no external power
source used, batteries
may be discharged.
Connect a fully charged external power
source and retry. See “Powering the
HiPer+” on page 2-2.
The receiver has an
external power source,
but internal batteries
are discharged.
Charge the batteries overnight. See
“Powering the HiPer+” on page 2-2.
The receiver may have
a defective charger or
defective internal
batteries.
If after charging your internal batteries
overnight, and your HiPer+ is not
powering, contact TPS Customer