HiPer+ Configuration
1-866-4TOPCON www.topconpositioning.com
2-21
Charging Internal Batteries
Use one of the following conditions for maximum
battery charge speed.
The receiver is turned off. Power Mode and Charger
Mode are set to Auto. See “Power Management” on
page 2-15 for setting these parameters.
The receiver is turned on. Power Mode is set to
External and Charger Mode is set to Auto.
1. Plug the power/charger cable into the power input
port.
2. Plug the power/charger cable into an available outlet.
3. Press the Reset key on the receiver. This will ensure
that the receiver is in Normal mode for charging. The
receiver will not charge in Zero Power Mode (see
“Zero Power Mode” on page 4-20 for more
information).
4. Leave overnight. A six-hour charge will charge the
batteries about 90%. A seven-hour charge will fully
charge the receiver. The internal batteries cannot be
overcharged.
5. When finished charging, set Power Mode to Auto.
NOTICE
If you remove a power supply cable before
setting Power Mode to Auto, the receiver will
be turned off. To turn it on, you will need to
connect an external power supply once again.