MINTER Configuration
1-866-4TOPCON www.topconpositioning.com
2-25
Figure 2-23. Receiver Configuration – MINTER Tab
Recording Interval parameter
This parameter specifies the message output interval into the
log file when the MINTER FN key (pressed for 1–5 seconds)
activates data logging. This setting is used not only when
logging a single log file, but also when logging receiver data
in AFRM mode. Values are 1–86400 seconds.
The default value is one second.
Elevation Mask for Log File parameter
This parameter specifies the minimum elevation angle for the
satellites whose data will be put in the receiver files logged
when pressing FN.
The default value is five degrees.
File Name Prefix parameter
This parameter specifies what prefix will be added to the
names of the receiver files created when pressing FN. The
prefix can be up to 20 characters long.
The default value is log.