Clearing the NVRAM
1-866-4TOPCON www.topconpositioning.com
4-19
In addition, the NVRAM is used to keep information about the
receiver file system. Note that after clearing the NVRAM, the
receiver's STAT LED will flash orange for a few seconds
indicating that the receiver is scanning and checking the file
system.
You can clear the NVRAM using either the MINTER or
PC-CDU.
Using MINTER to Clear NVRAM
1. Press the power key to turn off the receiver.
2. Press and hold the FN key.
3. Press and hold the power key for about one second.
Release the power key while continuing to hold the FN
key.
4. Wait until the STAT and REC LEDs are green
5. Wait until the STAT and REC LEDs blink orange.
6. Release the FN key while the STAT and REC LEDs
blink orange.
Using PC-CDU to Clear NVRAM
1. Connect your receiver and computer. See “Connecting
the HiPer+ and a Computer” on page 2-5 for this
procedure.
2. Click Tools->Clear NVRAM (Figure 4-15). The REC
LED rapidly flashes green and red; the STAT LED
flashes red.
Figure 4-15. Tools->Clear NVRAM
The receiver automatically disconnects once the NVRAM is
cleared.