EasyManua.ls Logo

Topcon HiPer Plus - Page 115

Topcon HiPer Plus
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the MINTER
1-866-4TOPCON www.topconpositioning.com
4-3
During data recording the REC LED is green.
If the REC LED is red, the receiver has run out of
memory, has a hardware problem, or contains an
improper OAF (see “Option Authorized File (OAF)” on
page 1-17 for more information on OAFs).
The REC LED blinks green each time data is written to
the internal receiver’s memory.
You set the data recording time interval using PC-CDU.
See “Recording Interval parameter” on page 2-25 for
information on setting this function.
Each time you turn off or on data recording, either a new
file opens or data appends to a particular file. See
Always Append to the File parameter” on page 2-26 and
“Files Creation Mode parameter” on page 2-26 for
information on setting this function.
Pressing the FN key for more than five and less than
eight seconds will turn the baud rate of serial port A to
9600. After about five seconds of pressing the FN key,
the REC LED becomes red. Release the FN key while
the REC LED is red (during the next three seconds).
Pressing the FN key for more than eight seconds has no
impact.
After loading new firmware or clearing the receiver’s
NVRAM, the receiver checks its internal file system.
During this operation, the REC LED flashes orange, and
the file system is not accessible for CDU (control display
unit) applications or for data recording. This operation
may require from fractions of a second to several
minutes, depending on the circumstances and the amount
of internal memory.

Table of Contents

Related product manuals