Configuration
Topcon HiPer+ Operator’s Manual
2-28
FN Key Mode parameter
You use these two radio buttons to program how the receiver
will react when pressing the FN key.
LED blink mode switch – pressing FN will toggle between
the MINTER’s normal/extended information modes and
start/stop data recording of Static survey.
FN pressed less than 1 second: changes the information
mode (Normal or Extended Information (EI) Modes).
FN pressed from 1 to 5 seconds: starts/stops recording
(Static post-processing mode).
Occupation mode switch – pressing FN (less than one
second) will insert into the corresponding log file a message
indicating that the survey type has been changed from static
to kinematic, or vice versa. If the REC LED blinks green, the
current mode is dynamic, if it blinks orange, the current
mode is static. For more details, see Table 4-1 on page 4-4,
and refer to the MINTER User’s Manual and PC-CDU
User’s Manual.
Initial Data Collection Dynamic Mode parameter
These radio buttons specify the starting occupation type
descriptor inserted at the beginning of receiver files logged.
You select Static or Kinematic to specify that the
corresponding log file will start with a static (STOP) or
kinematic (GO, Trajectory) occupation, respectively.
Data Recording Auto-start parameter
These radio buttons allow you to program your receiver’s
behavior in the event of a power failure.
Table 2-1 gives the different scenarios available and the
results after power is restored to the receiver. “Specified file”
refers to the file name entered in the Always append to file
parameter.