MINTER Configuration
1-866-4TOPCON www.topconpositioning.com
2-27
• Period – specifies the time duration of each log file created in
AFRM mode.
Values are 60 to 86400 seconds. The default value is 3600
seconds.
• Phase – specifies the “phase” (constant time shift) of creating
multiple log files in AFRM mode.
Values are 0 to 86400 seconds. The default value is zero
seconds.
• Files (total) – a counter that specifies how many multiple log
files must be created in AFRM until this mode automatically
turns off. This counter decrements on every file rotation until
it value becomes zero, then file rotation automatically stops.
The counter initializes with AFRM.
Note that a log file opens immediately after turning AFRM
on. This startup file is not considered a file rotation event; the
AFRM counter will not decrement.
Values are 0 to [2
31
-1]. The default value is 0 (zero). Zero
means that an unlimited number of log files will be created.
NOTICE
The receiver’s memory holds up to 256 files.
• Files (remain) – specifies the number of files left for the
receiver to create in AFRM.
Values are 0 to [2
31
-1]. The default value is zero.
• Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log
file. If this parameter is enabled, your receiver will erase the
file with the earliest file creation time/date. AFRM must be
enabled to use this FIFO (First-In, First-Out) feature.