Appendix A SCPI Command Reference
CONFigure subsystem
310 WCDMA Options Version 6.20
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence
:ISLA
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence
:ISLB
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence
:ISLC
Syntax
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLA
<string1>
Parameters
string1 is a string, defining the inner loop power control sequence.
The maximum length of
string1 is 20 characters.
The default for string1 is "11111111110000000000"
.
Description
This command defines the inner loop power control sequence for the user sequence
ISL1 that could be selected using the command
:CONF:WCDM:MEAS:RFTX:INNE:SEQ:SELE ISL1.
Query
The query form of this command will return the Inner loop power control sequence
associated with user defined sequence ISL1 and that could be selected using the
command :CONF:WCDM:MEAS:RFTX:INNE:SEQ:SELE ISL1
.
Example
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLA
"11111111110000000000"
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLA?
Value returned in this example: "11111111110000000000"
Syntax
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLB
<string1>
Parameters
string1 is a string, defining the inner loop power control sequence.
The maximum length of string1 is 20 characters.
The default for string1 is "10101010101010101010"
.
Description
This command defines the inner loop power control sequence for the user sequence
ISL2 that could be selected using the command
:CONF:WCDM:MEAS:RFTX:INNE:SEQ:SELE ISL2.
Query
The query form of this command will return the inner loop power control sequence
associated with user defined sequence ISL2 and that could be selected using the
command
:CONF:WCDM:MEAS:RFTX:INNE:SEQ:SELE ISL2.
Example
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLB
"11111111110000000000"
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLB?
Value returned in this example: "11111111110000000000"
Syntax
:CONFigure:WCDMa:MEASure:RFTX:INNErloop:SEQuence:ISLC
<string1>
Parameters
string1 is a string, defining the inner loop power control sequence.
The maximum length of string1 is 20 characters.
The default for string1 is "1111111111"
.