Appendix A SCPI Command Reference
FETCh Subsystem
370 WCDMA Options Version 6.20
:FETCh:WCDMa:RFTX:OPENloop[:DATA]?
:FETCh:WCDMa:RFTX:CODedomain:PCDe?
:FETCh:WCDMa:RFTX:CODedomain:IPOWer[:DATa]?
:FETCh:WCDMa:RFTX:CODedomain:QPOWer[:DATa]?
Example
:FETC:WCDM:RFTX:QMAX[:DATA]?
Returns the result in a string, e.g. 21.9,21.7,21.3
.
Syntax
:FETCh:WCDMa:RFTX:OPENloop[:DATA]?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The query form returns the result of a previous :MEASure:WCDMa:RFTX
:OPENloop[:STARt] measurement.
Example
:FETC:WCDM:RFTX:OPEN?
Returns the open loop power in dBm, e.g. -24.23
.
Syntax
:FETCh:WCDMa:RFTX:CODedomain:PCDe?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The command returns the result of a previous
:MEASure:WCDMa:CONT|ARR:RFTX:CODedomain:PCDe
measurement
command.
Example
:FETC:WCDM:RFTX:COD:PCD?
Returns the measured Peak Code Domain Error, e.g. -40.21
.
Syntax
:FETCh:WCDMa:RFTX:CODedomain:IPOWer[:DATa]?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The command returns the result of a previous :MEASure:WCDMa:RFTX
:CODedomain:IPOWer[:DATA|AVG] code domain I-power measurement.
Example
MEAS:WCDM:RFTX:COD:IPOW:AVG 10
:FETC:WCDM:RFTX:COD:IPOW?
Syntax
:FETCh:WCDMa:RFTX:CODedomain:QPOWer[:DATa]?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The command returns the result of a previous :MEASure:WCDMa:RFTX
:CODedomain:QPOWer[:DATA|AVG] code domain Q-power measurement.