PROCEDURE
1 Apply Never-Seez NSBT-8 to the thread of valve housing (002, Figure 10-28).
2 Put the relief valve (001) in the connecting piece (004) of the fuel rail (003).
3 Use the torque spanner and the socket wrench to torque the relief valve (001) to the
correct value, refer to section 16.1 Tightening instructions.
Fig 10-28 Fuel overpressure safety valve - installation
001
001
002
003
004
00829
CLOSE UP
None
X62DF
AA00-5562-01AAA-720A-A
Maintenance Manual Fuel rail - install the overpressure safety valve
Winterthur Gas & Diesel Ltd.
- 599 - Issue 002 2020-10