13.2.3 Hydraulic pipe exhaust valve - install
Periodicity
Description
Unscheduled
Duration for performing preliminary requirements 0.0 man-hours
Duration for performing the procedure 1.5 man-hours
Duration for performing the requirements after job completion 0.0 man-hours
Personnel
Description Specialization QTY
Engine crew Basic AR
Support equipment
Description Part No. CSN QTY
None
Supplies
Description QTY
Oil A/R
Spare Parts
Description Part No. CSN QTY
O-rings 2
O-rings 2
Hydraulic pipe 1
SAFETY PRECAUTIONS
CAUTION
Injury Hazard: Use approved equipment or sufficient personnel to lift and move the
hydraulic pipe.
CAUTION
Damage Hazard: Make sure that you do not cause damage the sealing faces or the
hydraulic pipes.
PRELIMINARY OPERATIONS
The hydraulic pipe exhaust valve must be removed, refer to section 13.2.1 Hydraulic pipe
exhaust valve - remove
X72DF
AA00-8460-00AAA-720A-A
Maintenance Manual Hydraulic pipe exhaust valve - install
Winterthur Gas & Diesel Ltd.
- 740 - Issue 002 2020-10