PROCEDURE
1 Operate the turning gear to get a tooth (004, Figure 14-1) of the intermediate wheel
opposite the applicable proximity sensor (001).
2 If necessary, put a mark on the applicable cable to identify its position.
3 Disconnect the applicable electrical connection from the applicable proximity sensor
(001).
4 Loosen the locknut (003).
5 Remove the proximity sensor (001) from the holder (002).