PROCEDURE
1 Attach the proximiy sensor (001, Figure 14-2) to the holder (002).
2 Turn the proximity sensor (001) fully down until the tip of the proximity sensor touches
the bottom of the holder (002).
NOTE: During installation/commissioning the clearance between the flywheel tooth
(001) and the holder (002) is set to 4
0
-0.2
mm.
3
Loosen the proximity sensor (001) a half turn to get a clearance of 4
0
-0.2
mm between
the flywheel tooth (004) and the bottom face of the proximity sensor.
4 Carefully tighten the locknut (003) with your fingers.
5 Connect the electrical connection to the proximity sensor (001). Refer to the mark made
before to identify the correct cable.
X62DF
AA00-9223-00AAA-720A-A
Maintenance Manual Crank angle sensor unit (supply unit) - install the proximity
sensor
Winterthur Gas & Diesel Ltd.
- 779 - Issue 002 2020-10