PROCEDURE
1 Disconnect the power supply to the defective IOM-10 on the related cylinder.
NOTE: WinGD recommends to make a software back-up from the LDU-20. This will
make sure that the correct configuration is loaded. For more data, speak to or
send a message to WinGD.
2 Remove the defective IOM-10.
3 Attach an UNSERVICEABLE label to the IOM-10.
CLOSE UP
None
X62DF
AA00-9606-00ADA-520A-A
Maintenance Manual IOM-10 - remove