EasyManua.ls Logo

WinGD X62DF - Page 94

Default Icon
897 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: Make sure that the piston (002) does not move above the limit of the red
groove (011).
7 Keep the applied pressure constant.
8 Loosen the round nut (004).
8.1 Get the applicable round bar (012) from the round bar kit.
8.2 Put the round bar (012) through the slot (005) into a hole of the round nut (004).
8.3 Turn the round nut (004) back the related number of turns.
8.4 Remove the round bar (012).
9 Release the pressure on the HP oil pump or on the hydraulic unit to zero.
10 Disconnect the pre-tensioner from the HP oil pump or from the hydraulic unit.
11 Remove the pre-tensioner from the elastic stud (008).
12 If necessary, fully remove the round nut (004) from the elastic stud (008).
CLOSE UP
None
X62DF
AA00-0000-00AAA-510A-A
Maintenance Manual Loosen a round nut with a pre-tensioner
Winterthur Gas & Diesel Ltd.
- 94 - Issue 002 2020-10

Table of Contents

Related product manuals