9.3 Automatic Backup Function
9-11
Operation Explanation
1 Turn ON the NX100. If the auto backup function is already set valid, insert a Compact-
Flash.
2 Insert a CompactFlash in the
CompactFlash slot on the pro-
gramming pendant.
3 Change the security mode to
the management mode.
4 Select {SETUP} under the
main menu.
5 Select {AUTO BACKUP SET}. The AUTO BACKUP SET display appears.
A. RESERVE TIME BACKUP
Set the backup function to valid or invalid in a specified cycle
from a specified starting time.
Each time [SELECT] is pressed, "INVALID" and "VALID" are
displayed alternately.
The reserve time can be set by inputting values in B,C and D
in the display. Every time values are set to these three items,
reset the RESERVE TIME BACKUP to INVALID. If these
settings are incorrect, the RESERVE TIME BACKUP cannot
be reset to VALID. If so, check and then change the values to
the correct settings.
B. BASE TIME
Specify the reference time to start reserve time backup.
The time elapsed from the reference time for a BACKUP
CYCLE period is recognaized as the BACKUP TIME. The first
automatic backup is performed at the first BACKUP TIME
after the power of the NX 100 is turned ON. The automatic
backup after the first time, is performed at the interval of
BACKUP CYCLES.
The reference time ranges from 0:00 to 23:59.
A
B
C
D
F
H
I
J
G
E
K
L
M
N
SORT FILE

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals