11.2 Addition of Base and Station Axes
11-18
Connection Setting
In the CONNECTION window, each axis in respective control group is specified to be
connected to which connector of the SERVO board, or to which brake of the contactor unit, or
to which converter.
Operation Explanation
1 Confirm type of each control
group in the CONNECTION
window.
Connection status of each control group is displayed.
2 Select the connection item of
desired control group.
(Continued on the next page.)
The settable items are displayed.
When the item is selected, the window returns to the CONNEC-
TION window.
-It is possible to change the connection freely between each axis
of each control group and each connector (CN) of a SERVO
board. The number in [ ] represents the axis number, and it
indicates which axis is to be connected with which connector.
-It is possible to change the connection freely between each axis
of each control group and each brake (BRK) of a contactor unit.
The number in [ ] represents the axis number, and it indicates
which axis is to be connected with which brake.
-It is possible to change the connection freely between each axis
of each control group and each converter (CV). The number in
[ ] represents the converter number, and it indicates which axis is
to be connected with which converter.
In this example, S1 (station) is to be connected as shown in the
following manner:
3 Select the desired item.
4 Press [ENTER] in the CON-
NECTION window.
The setting in the CONNECTION window is completed and the
window moves to the AXES CONFIG window.
CONNECT
SV CN<1 2 3 4 5 6 7 8 9> TU BRK <1 2 3 4 5 6 7 8 9> CN<1 2 3 4 5 6 7 8 9>
R1
: #1
S1 : #
1
[
1 2 3 4 5 6
---
] #1 [
1 2 3 4 5 6
---
]
CV[
1 1 1 1 1 1
---
]
[
---
] #1
---
[
---
]
---
1 2
---
]
---
2 3
CV[
Main Menu
ShortCut
Choose the number of servo board which conne
Control group which
is set as "NONE" in
the CONTROLGROUP
window is not shown.
--
1 2
-
1st axis SERVO Board (SV #1), Connector (7CN)
Contactor Unit (TU #1), Brake Connector (BRK7)
Converter (CV #2)
2nd axis
SERVO Board (SV #1), Connector (8CN)
Contactor Unit (TU #1), Brake Connector (BRK8)
Converter (CV #3)

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C