Displaying and Changing System Feature Information 129
Stopping Data
Monitoring
You can stop data monitoring by the roving analysis port and remove the
monitor port from the roving analysis set up by using the
stop
command
on the Analyzer menu.
To stop data monitoring by the roving analysis port and remove the
monitor port:
At the Top-level menu, enter:
feature analyzer stop
Enabling and
Disabling Broadcast
Storm Control
You can enable or disable broadcast storm control for the Switch unit or
stack using the
broadcastStormControl
command on the Feature
menu.
To enable or disable broadcast storm control for the Switch:
1
At the Top-level menu, enter:
feature broadcastStormControl
The following prompt is displayed:
Enter new value (disable, enable) [disable]:
2
Enter
enable
or
disable
.
If you enter
enable
, the following prompt is displayed:
Enter rising threshold in pps (0-200000) [2976]:
3
Enter the value for the rising threshold in packets per second.
The following prompt is displayed:
Enter falling threshold in pps (0-200000) [1488]:
4
Enter the value for the falling threshold in packets per second.
The following prompt is displayed:
Enter time period in seconds (10-60) [30]:
5
Enter the time period value in the range of 10 to 60 seconds.

Table of Contents

Other manuals for 3Com SuperStack II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3Com SuperStack II and is the answer not in the manual?

3Com SuperStack II Specifications

General IconGeneral
Brand3Com
ModelSuperStack II
CategorySwitch
LanguageEnglish

Related product manuals