88 C
HAPTER
 3: W
ORKING
 W
ITH
 
THE
 W
EB
 I
NTERFACE
Enabling the Roving Analysis System
The Roving Analysis Setup page allows you to enable the roving analysis 
system. To do this:
1
From the 
Roving Analysis State 
listbox, select 
Enabled
.
2
Click 
Apply
.
Resetting All the
Units in the Stack
You can reset all the Switch units in the stack using the Reset page. 
To access the page:
1
Click the 
Configuration
 icon on the side-bar.
2
Click the 
Reset
 hotlink. The Reset page is displayed.
To reset the stack, select 
Yes
 and then click 
Apply
.
What Happens During a Reset?
Resetting the Switch units in the stack simulates a power-off/on cycle. 
You may want to do this if you need to:
■
Remove all the Learned entries in the Switch Database (SDB).
■
Reset the statistic counters of the stack. 
CAUTION: 
Resetting the stack causes some of the traffic being 
transmitted over the network to be lost. It also clears all Learned entries 
from the Switch Database.
The stack takes about 10 seconds to reset. While the stack is resetting, 
you cannot communicate with it.
Initializing All the
Units in the Stack
You can initialize all the Switch units in the stack using the Initialize page.
To access the page:
1
Click the 
Configuration
 icon on the side-bar.
2
Click the 
Initialize
 hotlink. The Initialize page is displayed.
To initialize the stack, select 
Yes
 and then click 
Apply
.
What Happens During an Initialization?
Initializing the Switch units in the stack returns them to their default 
(factory) settings. The only information that does not return to its default