NoteAction
Separate the cabling in front of the computer, cut
cable ties if necessary.
CAUTION
Be careful not to bend or break the cables and air
hoses.
2
xx1500000371
Disconnect the connectors:
A31.USB (X10)
A31.X9 (X9)
A31.X6 (X6)
A31.X5 (X5)
A31.X4 (X4)
A31.X3 (X3)
A31.XS1 (X1)
A31.SERVICE (X2)
3
Cut cable ties from the disconnected cables if
necessary.
4
(Depending on which connection is installed)5
Disconnect the connector:
Profibus/S: A32.2
Ethernet/IP/S: A32.1
ProfiNet/S: A32.3
xx1500000386
Loosen the nuts holding the computer.6
Nut 9ADA267-5 M5 Steel 8-A2F
Gently push the computer upwards a little bit to
release the latches from the recesses.
7
Disconnect the connection (underneath com-
puter): A35.J1 D-NET
8
Tilt the computer out and remove it from the con-
troller.
9
Continues on next page
Product manual - IRB 14000 305
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.1 Replacing the computer
Continued