6 SERVICE, DISMANTLING, ASSEMBLY 6.5 ASSEMBLY
2 Adjusting the unbalance sensor
A
G
G08734A1
a Fit the sensor into the holder. Do not forget the nut.
Sensor
Nut
b Adjust the sensor so that a value of 1,5 appears on the display.
c When correct distance is achieved tighten the nut
against the holder.
Fit the cover (see previous page).
Nut.
Adjustment value for the sensor is; 12 mA ± 1mA.
For more details see 8.3 Connection List, page 149 and
752 Unbalance sensor (optional)., page 156.
+ = brown or red
J = black or white
0V = blue
24 V DC