show serial_port
Purpose Used to display the current serial port settings.
Syntax show serial_port
Description This command displays the current serial port settings.
Parameters None.
Restrictions None.
Example usage:
To display the serial port setting:
AT-9724TS:4# show serial_port
Command:show serial_port
Baud Rate : 1 1 5 2 0 0
Data Bits : 8
Parity Bits : N o n e
Stop Bits : 1
A u t o - L o g o u t : 10 mins
A T - 9 7 2 4 T S : 4 #
config serial_port
Purpose Used to configure the serial port.
Syntax config serial_port {baud_rate [115200] | auto_logout [never | 2_minutes | 5_minutes |
10_minutes | 15_minutes]}
Description This command is used to configure the serial port’s baud rate and auto logout settings.
Parameters baud_rate [115200] The serial bit rate that will be used to communicate with the management host.This
parameter is fixed at 115200.
never – No time limit on the length of time the console can be open with no user input.
2_minutes The console will log out the current user if there is no user input for 2 minutes.
5_minutes The console will log out the current user if there is no user input for 5 minutes.
10_minutes The console will log out the current user if there is no user input for 10 minutes.
15_minutes The console will log out the current user if there is no user input for 15 minutes.
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure baud rate:
AT-9724TS:4# config serial_port baud_rate 115200
Command:config serial_port baud_rate 115200
S u c c e s s
A T - 9 7 2 4 T S : 4 #
21
Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch

Table of Contents

Other manuals for Allied Telesis AT-9724TS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9724TS and is the answer not in the manual?

Allied Telesis AT-9724TS Specifications

General IconGeneral
MAC address table16000 entries
Packet buffer memory2 MB
Maximum data transfer rate88 Gbit/s
Full duplexYes
Dimensions (WxDxH)440 x 210 x 44 mm
Power requirements100-240V AC/50-60Hz
Management platformSNMP, RMON
Networking featuresIEEE 802.3 10T Ethernet, IEEE 802.3u 100TX Ethernet, IEEE 802.3ab 1000T Ethernet, IEEE 802.3z 1000X Ethernet
Connectivity technologyWired
DHCP featuresDHCP client
Security algorithmsSSH
Switch typeManaged
Switch layerL3+
SFP/SFP+ slots quantity4
Basic switching RJ-45 Ethernet ports quantity24
Memory typeSDRAM / Flash
Flash memory16 MB
Internal memory256 MB
Power consumption (typical)90 W
CertificationUL 1950 FCC Class A CSA 22.2 No. 950 EN55022 Class A EN 60950 (TUV) EN50082-1 CE
Storage temperature (T-T)-25 - 55 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight3200 g