8 Parameter detail setup
116 © Copyright Reserved Autonics Co., Ltd.
8.7 RESERVATION SETUP (Reservation setting)
You can set reservation parameters of KRN100.
Set the item related reservation (reservation type, reservation period, reservation time).
Move to RESERVATION SETUP with , keys, press key to enter
RESERVATION SETUP.
Parameter list
Parameter Setting range Factory default
Reservation Type (Reservation record)
Disable ↔ Single ↔ Repeat
Reservation Period (Reservation record
2000y 01m 01d to 2099y 12m 31d --
Reservation Time (Reservation record time)
00h 00m 00s to 23h 59m 59s
※ Shaded parameters are affected by set value of other parameters. Please refer to specific
descriptions of each parameter.
8.7.1 Reservation Type (Reservation record)
This function is to set reservation time. At the set time, it starts/stops recording automatically.
You can select reservation record either Repeat(Repeat ON/OFF) or Single(Single ON/ OFF).
When selecting reservation record, ‘Reservation Period(Reservation record period)’ and
‘Reservation Time(Reservation record time)’ are activated. When reservation record is set,
icon flashes with (recording) or (stop recording) icon.
icon tuns OFF when reservation setting is ‘Disable’.
Setting range: Disable ↔ Repeat ↔ Single
Factory default: Disable
(1) Repeat(Repeat ON/OFF)
From start recording date to end recording date, it records data at from the set start time to
the set end time. End time must be later than Start time.