EasyManua.ls Logo

Autonics krn100 series - User Manual

Autonics krn100 series
151 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Thank you for purchasing an Autonics product.
This user manual contains information about the product and its proper use,
and should be kept in a place where it will be easy to access.
www.autonics.com
User Manual
Recorder
KRN100 Series
MCR-KRN100U1-V1.1-2202US

Table of Contents

Other manuals for Autonics krn100 series

Questions and Answers

  • G
    Gregory PowellAug 16, 2025
    What to do if USB memory is not recognized by Autonics krn100 Measuring Instruments?
    • D
      Derek WilliamsAug 16, 2025
      If the USB memory is not recognized by the Autonics Measuring Instruments KRN100, ensure that the USB memory's file system is formatted as FAT16 or FAT32. Also, if the USB memory has multiple partitions, the KRN100 will only recognize the first partition.
  • M
    Michael KingAug 18, 2025
    How to troubleshoot incorrect sensor input value on Autonics Measuring Instruments?
    • S
      Sharon MataAug 19, 2025
      If the sensor input value is incorrect on the Autonics Measuring Instruments KRN100, verify that the sensor input settings are correct in the INPUT SETUP. Also, turn off the power, remove the input cards, and check the jumper pin settings according to the input specification.
  • L
    Logan RiceAug 22, 2025
    How to fix Ethernet connection issues with Autonics krn100 Measuring Instruments?
    • M
      Marissa LambAug 22, 2025
      If you cannot connect communication by Ethernet on Autonics Measuring Instruments KRN100, you should check the communication line connection and reset it as described in ‘8.4 COMMUNICATION SETUP (Communication setting).’
  • B
    brooksdianaAug 25, 2025
    What to do if RS485 communication fails on Autonics Measuring Instruments?
    • A
      amy30Aug 26, 2025
      If you cannot connect communication via RS485 communication on Autonics Measuring Instruments KRN100, check that the communication line’s A and B signal polarity is connected correctly. Then, reset it as described in ‘8.4 COMMUNICATION SETUP (Communication setting).’
  • H
    Heather WashingtonAug 28, 2025
    Why is Autonics krn100 recording old data?
    • D
      dcohenAug 28, 2025
      If the Autonics Measuring Instruments KRN100 records former digital data instead of the current time's data, it means the record memory status icon ( or ) is active, indicating that it's recording former digital data. To cancel this, pause and restart the recording. Also, adjust the record settings for proper operation.
  • J
    Jonathan HuntAug 31, 2025
    How to correct date and time on Autonics krn100 Measuring Instruments?
    • J
      jonescoryAug 31, 2025
      If the displayed date and time are incorrect on the Autonics Measuring Instruments KRN100, reset the date and time. Note that the KRN100 has a date and time error margin of ±2 minutes per year and is usable until the year 2100.
  • C
    Christina NguyenSep 3, 2025
    Why is the printout blurry on Autonics Measuring Instruments?
    • A
      andreaparkerSep 3, 2025
      If, in graph mode, the printout for lines and letters is unclear and spread on the Autonics Measuring Instruments KRN100, replace the ink cartridge.
  • A
    Andrea GrantSep 5, 2025
    What does the red star on Autonics Measuring Instruments mean?
    • D
      Dave MartinezSep 5, 2025
      If the recording paper's terminal mark, a red star shape, is displayed on the Autonics Measuring Instruments KRN100, the recording paper should be replaced. This indicates that only 330mm of recording paper is left.
  • J
    Jessica JacksonSep 9, 2025
    How to troubleshoot a blank LCD screen on Autonics Measuring Instruments?
    • Q
      qwrightSep 9, 2025
      If the Autonics Measuring Instruments KRN100 does not display anything on the LCD screen and does not operate when powered on, check the power supply and ensure the power connector is connected correctly.
  • B
    burchmelissaSep 12, 2025
    What to do if Autonics Measuring Instruments freezes on boot screen?
    • K
      Kristin SosaSep 12, 2025
      If the Autonics Measuring Instruments KRN100 does not change from the booting screen to the normal operation screen after being powered on, the SD card inside the KRN100 may have a problem. Please contact our service center.

Summary

Preface

User Manual Symbols

Safety Considerations

Overview

Feature of KRN 100

Details the key features and capabilities of the KRN100 recorder.

Component and sold separately

Lists the included components and separately sold accessories for the KRN100.

Ordering information

Provides details on how to order the KRN100 recorder and its configurations.

Part description

Identifies and describes the various parts and components of the KRN100 unit.

Specification

KRN100

Presents the technical specifications for the KRN100 recorder unit.

I;O card

Details the specifications and types of input/output cards available for the KRN100.

Input specification and measuring range

Outlines the input specifications and measurement ranges for various sensors.

Dimensions

KRN100

Provides the physical dimensions of the KRN100 unit.

Panel cut-out

Specifies the required panel dimensions for mounting the KRN100.

Bracket

Illustrates the dimensions and design of the mounting bracket.

Connection

KRN100

Details the rear view of the KRN100 and the function of each slot.

I;O card

Illustrates the connection diagrams for various I/O cards used with the KRN100.

Installation

Installation place

Provides guidelines for selecting an appropriate installation location for the KRN100.

Installation

Describes the process of physically installing the KRN100 unit.

USB to Serial driver

Details the installation process for the USB to Serial driver.

Display

Initial booting screen

Describes the screens displayed during the KRN100's initial power-on sequence.

Screen layout

Explains the division of the KRN100's screen into status and measurement display areas.

Operation

Screen display

Details how the KRN100 displays measuring values in various modes.

Special operation for record

Covers special functions for recording, such as start/stop and manual feed.

Parameter setting group

Outlines the order and navigation for setting the KRN100's parameters.

Parameter detail setup

INPUT SETUP(Input setting)

Details how to configure input specifications, scales, and error correction.

ALARM SETUP (Alarm setting)

Covers configuring alarm types, hysteresis, delays, and output methods.

DIGITAL INPUT SETUP(Digital input setting)

Explains how to set up digital input functions and operation status.

COMMUNICATION SETUP (Communication setting)

Details parameters for RS485, Ethernet, and USB communication setup.

RECORD SETUP (Record setting)

Covers settings for record mode, speed, language, and paper handling.

SYSTEM SETUP (System setting)

Allows configuration of system parameters like date, time, and backlight.

RESERVATION SETUP (Reservation setting)

Explains how to set up scheduled recording based on time and period.

FILE;MEMORY SETUP(File;Memory setting)

Covers managing parameter files, memory status, and USB data transfer.

USER INFORMATION SETUP(User information setting)

Details user management, password settings, and firmware upgrades.

RECORD BACKUP_ SETUP (Backup data record setting)

Describes how to back up data, manage lists, and select print modes.

DAQMaster

Overview

Introduces DAQMaster as an integrated device management program.

Features

Lists the key features and capabilities of the DAQMaster software.

Dedicated KRN100 functions

Highlights specific KRN100 functions available when communicating with DAQMaster.

Maintenance

Ink cartridge replacement

Provides step-by-step instructions for replacing the ink cartridge.

Recording paper replacement

Details the procedure for replacing the recording paper roll.

Troubleshooting

Error message

Lists common error messages and their corresponding troubleshooting steps.