8 Parameter detail setup
© Copyright Reserved Autonics Co., Ltd. 111
8.5.18 PenX(color) ON Time (Ink cartridge point delay time)
By setting the dot delay time of the ink cartridge, you can adjust the darkness of the ink printed
on the paper. The lower the value, the lighter the display, and the higher the value, the darker the
display. The higher the value, the shorter the life of the ink cartridge.
Setting range: 1 to 25
Factory default: 13
The setting values are maintained even after initialization in the [FILE/MEMORY SETUP-Load
Set File] menu. This menu cannot be set by communication.